logo
products

Pump-Type HCL Gas Detector Wall Mounted Fixed Gas Detector with High Accuracy Continuous Monitoring

基本情報
起源の場所: 中国
ブランド名: SAFEGAS
証明: ATEX/IECEX
モデル番号: YT-98H
最小注文数量: 1
価格: 交渉可能
パッケージの詳細: カートン(43*27*15cm)
受渡し時間: 3営業日
支払条件: T/T、ウェスタンユニオン
供給の能力: 月に3000個
詳細情報
検出されたガス: HCL 検出原理: 電気化学
力: 12から24V DC 正確さ: ≤±2-5%fs
応答時間(T90): 15歳から30歳 再現性: ≤±1%
ポンプの流れ: 0.35-0.5 L/min 温度: 20°Cから55°C
湿度(凝縮なし): 0~95%RH オプションアラーム: 鳴き声,アラーム状態表示
サンプリング方法: 内部ポンプ付き
ハイライト:

Pump-Type HCL Gas Detector

,

Wall Mounted Fixed Gas Detector

,

High Accuracy Multi Gas Detector


製品の説明

Pump-Type HCL Detector - Wall Mounted Continuous Monitoring System
About Hydrogen Chloride (HCL)

Hydrogen chloride (HCL) is a colorless, irritating, corrosive, and asphyxiating gas that is both volatile and unstable. As an important industrial chemical, HCL is used in the production of dyes, fragrances, pharmaceuticals, various chlorides, and corrosion inhibitors.

High-purity HCL gas is widely employed in the electronics industry. The gas has a suffocating odor and is highly irritating to the upper respiratory tract, with corrosive effects on eyes, skin, and mucous membranes. Continuous HCL concentration monitoring is essential to prevent leaks that could endanger personnel safety.

Maximum allowable concentrations: China (MAC) 15 mg/m³ (9.2 ppm); US TLV-C 7.5 mg/m³ (4.6 ppm).

Due to HCL's volatile and unstable nature, pump-type detectors that actively draw gas samples provide faster and more reliable detection.

YT-98H/YT-98H-A Fixed Gas Detector

The YT-98H is a built-in pump-suction single and multi-gas detector featuring IECEx and ATEX certification with non-contact magnetic wand design. Suitable for installation and operation in explosion-proof areas and the oil & gas industry, it offers 3-wire 4-20mA output with relays, plus HART and Modbus protocols for compatibility with most control systems. Optional wireless functionality enables remote data viewing on laptops, mobile phones, or cloud systems.

Product Advantages
  • Simultaneous detection of up to 6 different gases
  • Reduces multiple installations in complex multi-gas environments, saving time and resources
  • 2.4-inch industrial-grade high-definition color screen with 320*240 resolution and 120-degree viewing angle
  • Optional wireless module for cloud platform data upload, environmental protection bureau integration, and SMS alerts with unlimited transmission distance
  • Internal suction pump for fast response times
  • Full software automatic verification and zero calibration functions for enhanced accuracy and reliability
  • Standard 4-20mA current signal, RS485 Modbus signal, and relay signal output
  • Infrared remote control for detector operation and settings modification
  • Optional sound and light alarm function when reaching alarm points
Product Images - YT-98H (with display)
Pump-Type HCL Gas Detector Wall Mounted Fixed Gas Detector with High Accuracy Continuous Monitoring 0
Pump-Type HCL Gas Detector Wall Mounted Fixed Gas Detector with High Accuracy Continuous Monitoring 1
Pump-Type HCL Gas Detector Wall Mounted Fixed Gas Detector with High Accuracy Continuous Monitoring 2
Product Images - YT-98H-A (with display and alarm light)
Pump-Type HCL Gas Detector Wall Mounted Fixed Gas Detector with High Accuracy Continuous Monitoring 3
Pump-Type HCL Gas Detector Wall Mounted Fixed Gas Detector with High Accuracy Continuous Monitoring 4
Pump-Type HCL Gas Detector Wall Mounted Fixed Gas Detector with High Accuracy Continuous Monitoring 5
Pump-Type HCL Gas Detector Wall Mounted Fixed Gas Detector with High Accuracy Continuous Monitoring 6
Technical Specifications
Gas Detected HCL
Detection Principle Electrochemical
Installation Method Wall-mounted, piping type, flow-type (according to detected environment)
Measurement Range 0-10, 20, 50, 100PPM 0-500, 1000, 2000PPM
Resolution 0.1PPM, 1PPM
Accuracy ≤±2-5%FS (depending on specific sensor)
Signal Output 4-20mA, RS485, relay
Response Time (T90) 15-30s (depending on specific sensor)
Recovery Time ≤10s
Repeatability ≤±1%
Display 2.4-inch color display, resolution 320*240
Operating Language English/Chinese
Display Content Gas molecular formula, concentration, unit, pump status, etc.
Temperature Range -20°C to 55°C
Humidity Range 0-95%RH
Explosion-Proof Certification IECEX: Ex db IIC T6 Gb
ATEX: Ex db IIC T6 Gb
Degree of Protection IP66
Alarm Mode Sound, light
Operating Time 24h continuous operation
Dimensions 43*27*15cm
Weight 4.6kg
Why Choose Safegas?

Safegas specializes in the design, production, and sales of environmental monitoring equipment and systems with 16 years of industry experience. With gas detectors as our core product, we provide complete production lines and solutions tailored to various industries including Oil, Chemical, Pharmaceutical, Energy, Environmental Protection, Electronics, Municipal Engineering, Agriculture and Forestry, and Household Appliances.

Pump-Type HCL Gas Detector Wall Mounted Fixed Gas Detector with High Accuracy Continuous Monitoring 7

Through nearly two decades of rapid development, Safegas has become an influential supplier of environmental monitoring equipment and systems in domestic and international markets.

Our management philosophy centers on "Market orientation, Innovation motivation, Quality survival, Development growth." Through friendly, open, and strict corporate culture with standardized management, we've assembled talented teams in product development, production, and maintenance who deeply understand customer-oriented principles.

Pump-Type HCL Gas Detector Wall Mounted Fixed Gas Detector with High Accuracy Continuous Monitoring 8

Leveraging years of measurement experience and Safegas solutions, combined with independent R&D, cooperative development, and overseas technology integration, our products achieve domestic advanced standards and compete effectively with international brands.

Pump-Type HCL Gas Detector Wall Mounted Fixed Gas Detector with High Accuracy Continuous Monitoring 9
Frequently Asked Questions
Q1: Are you a manufacturer or trading company?
A1: We are a professional manufacturer specializing in gas detectors for more than 10 years.
Q2: What is the MOQ?
A2: Usually it is 1 piece.
Q3: How about the quality of your products?
A3: Our products use imported sensors and components and are fully certified.
Q4: How long is the warranty time of the products?
A4: The warranty period is 1 year from factory date, with lifetime maintenance support.

連絡先の詳細
Daphne Luo

電話番号 : +8613072743898

ワッツアップ : +8613072743898